Author: Thomas Schilcher
Phone: +41 56 310 4593
Updated: 18.06.2019
Printer friendly version
|
|
|
SLS DBPM System
Operating Modes for SLS Storage Ring
Mode | Description | Digital Downconverter Output Rate | Bandwidth *) |
turn-by-turn | triggered mode, turn-by-turn data, up to 8192 turns available | 1.0409 MHz | 550 kHz |
ramp 250 ms | triggered mode, covers a time range of up to 251.8 ms (8192 data points) | 32.53 kHz | 15 kHz |
ramp 500 ms | triggered mode, covers a time range of up to 503.6 ms (8192 data points) | 16.26 kHz | 7.5 kHz |
ramp 2 s | triggered mode, covers a time range of up to 2.014 s (8192 data points) | 4.066 kHz | 0.69 kHz |
closed orbit | continuous data stream | 4.066 kHz | 0.69 kHz |
Single Bunch Performance of DBPM
intensity plot of ARIDI-BPM-12LD (Ibeam = 0 - 20 mA):
linear plot (postscript file)*)
logarithmic plot (postscript file)*)
*) only accessible within PSI network
Author: Thomas Schilcher Phone: +41 56 310 4593 Updated: 18.06.2019
|